Application
The vent valve is installed vertically on the suction side of a pump at the top of a tank or at the highest point of an installation in order to release the entrapped air. The valve remains open as long as there is an air flow, but closes as soon as the product reaches the valve to prevent the product from escaping.
Operating principle
The density of the freely floating ball is less than the density of water, when the product reaches the valve, the ball floats on its surface. As the product rises, the air can escape till the ball is forced to close the valve.
Design and features
Easy assembly/disassembly - clamp design, no tools required.
Standard connection: welding.
Materials
Parts in contact with the product AISI316L
Other parts (no contact with the product) AISI304
Clamp gasket EPDM
Ball Natural Rubber
Valve surface finish Mirror polish
Options
Available connections: Clamp, SMS, DIN, etc.
Optional adjustment for tank emptying.
Technical specifications
Max. pressure 10 bar
Max. temperature 90°C (NR)
Standard valve DN-1"
Low liquid flow speed at the valve inlet is advised for a better positioning of the ball.