Application
The 72700 valve is a check valve that allows the fluid to flow through it only in one direction.
These valves are normally used to prevent the loss of prime of a pump and to avoid water hammer. The valve is widely used in water loops.
Operating principle
The check valve opens when the pressure of the fluid exceeds the cracking pressure exerted by the spring. When the two pressures are compensated, the valve closes. A higher counterpressure closes the valve.
When there are two pumps operating alternately, the check valves are installed at the outlet of each pump to prevent the backflow when the pump is stopped. The obturation shaft is provided with a perforation for minimum circulation flow to avoid water stagnancy.
Design and features
3A certified valve.
Easy assembly/disassembly by loosening the clamp.
Reduced size design.
Standard connections: Clamp OD.
Traceability of components.
Materials
Parts in contact woth the product AISI 316L
Other st.st. parts AISI 304
Spring AISI 301
Gasket EPDM according to FDA 177.2600
Internal surface finish Ra ≤ 0,5 µm
External surface finish machined
Options
Gaskets: NBR, FPM or PTFE.
Welding connections
Perforation in the valve cone.
Material and surface roughness certificates.
ATEX version.
Technical specifications
Sizes DN 1" - DN 4"
Working temperature -10 ºC to +121 ºC (EPDM) 14 ºF to 250 ºF
+140 ºC (SIP, max. 30 min) 284 ºF
Max.working pressure 10 bar 145 PSI
Opening pressure 0,3 bar (DN 1") 4,35 PSI
0,2 bar (DN 1½") 2,9 PSI
0,1 bar (DN 2" - DN 4") 1,45 PSI