Hygiene is an essential part of the processes of the food processing, cosmetics, pharmaceutical industries  as a correct cleaning  of all the  elements is required (tanks,  pipes, pumps, etc.).  We offer an automated CIP units, correctly selected, designed for customers' plants to guarantee a controlled cleaning and efficiency without disassebling the plant.

Disign and features

PORTABLE CIP DESIGN

It consists of the following elements:
- Two AISI 316 tanks, jacketed, of 250L for the prepration of cleaning solutions.
  Conical bottoms.
- Electric heaters inside the tank.
- Peristaltic, piston or membrane pumps for concentrates dosing.
- 4Kw Hyginox SE impulsion pump.
- AISI 316 collectors with pneumatic butterfly valves with C-TOP.
-  AISI 304 frame with wheels.
- Return filter.
- Temperature control inside the tanks and conductivity control in the return line. 
- Level control in the tanks.
- Flow control in the return line.
- Pressure gauge at the pump impulsion.
-  6" display allows touch screen control.
-  PLC Siemens system control.
- 5 programmes: preparation, short tank cleaning, short line cleaning, tank long cleaning and long line cleaning. Manual valve activation. Plant state displaying. Change of parameters.
- Tested and verified in our test house.

ONE LINE STATIC CIP UNIT DESIGN

It consists of the following elements:
- Two  AISI 316 tanks, jacketed, of 1000L for the preparation of cleaning solutions.
  Conical bottoms.
- One  AISI 304 tank, not jacketed, of 1500L for recovered water. Conical bottoms.
- Heating by a steam heat exchanger, with a graduated acting steam valve, drains...
- Peristaltic, piston and membrane pumps for concentrates dosing.
-  5.5Kw Hyginox SE impulsion pump.
-  AISI 316 collectors with pneumatic butterfly valves with C-TOP.
- AISI 304 frame with adjustable legs.
- Filter in return line.
- Temperature control inside the tanks and conductivity control in the return line.
- Level control in the tanks.
- Flow control in the return line.
- Pressure gauge at the pump impulsion.
-  10" display allows touch screen control.
- PLC Siemens system control.
- 5 programmes: preparation, short tank cleaning, short line cleaning, tank long cleaning and long line cleaning. Manual valve activation. Plant state displaying. Change of parameters.
- Tested and verified in our test house.

Options

Recirculation inside the tanks by means of a pump.
Additional tank for sterilant alternatively inline dosing. 
Handshakes between the CIP control panel and other control systems on the plant.
Valves without feed back.
Use of double seat or single seat valves instead of the butterfly valves.
Tubular heat exchanger.
Other tank configurations (2  simultaneous lines, bigger volumes...).
Flow control.
Logging  of the operating data.
Fixed plant (not skidded) due to the size.

Materials

Parts in contact with the media                     AISI 316L
Other parts                                                 AISI 304
Insulation                                                    rock wool
Gaskets (valves, pumps, connections)              EPDM