The C-TOP control unit with the AS-i (Actuator Sensor Interface) communication is designed for automation of valves. This option is available for the valves supplied with C-TOP units (ball valve, butterfly valve, seat valves). 

Request information

C-TOP AS-i Control Unit C-TOP AS-i

Operating principle

The AS-i is a fieldbus system that allows to connect a network of actuators and sensors (detectors) to a control device of a higher level (Master).

Power supply, one or several master modules, bus cable (preformed cable) and the C-TOP prepared for AS-i connection (special internal card, connection cable, AS-i insulation displacement connector) are necessary to create an AS-i network.

The As-i fieldbus is provided with voltage by a power supply source.

The sensors and electrovalves connected to the fieldbus are controlled by the master module.
Every Master sends the information to the PLC and controls up to 62 units (C-TOP's).

The interconnection is made with a preformed cable. The preformed cable is used for transmitting information as well as a power supply of the electrovlaves and detectors. An AS-i version C-TOP must always be installed with inductive detectors and 24V DC.
The preformed cables and bus cables of the C-TOP's are connected by means of insulation displacement connectors, thus, the cables connecting every C-TOP with the control system are not necessary.

Design and features

AS-i bus offers an easy, fast and economic interconnection of sensors and electrovalves (actuators). It facilitates the assembly and the start-up of the plant as the cabling is considerably reduced. It also reduces the start-up time as well as it helps to avoid possible installation errors.
The C-TOP units can be set up according to the customer’s requirements.

Configuration of solenoid valves
. Single-acting actuation - 1 solenoid valve
. Double-acting actuation - 2 solenoid valves
. Mixproof valve – 3 solenoid valves*

Configuration of detectors
The valve position is detected by means of inductive detectors.
. 1 position (closed or open valve) - 1 detector
. 2 positions (closed and open valve) - 2 detectors
. 3 positions (open valve, closed valve, Mixproof seat cleaning) - 3 detectors*

*Depending on the model

Materials

Base: PPO + GF
Cover :Transparent PC
Gaskets: EPDM 

Options

External detector (Detection of the seat lift when it cannot be detected inside the C-TOP).
Materials for work under extreme conditions (PSU cover).
Segment with 4 inputs y 4 outputs in AS-i 2.1 (31 slaves).

Documents

Operating principle

The AS-i is a fieldbus system that allows to connect a network of actuators and sensors (detectors) to a control device of a higher level (Master).

Power supply, one or several master modules, bus cable (preformed cable) and the C-TOP prepared for AS-i connection (special internal card, connection cable, AS-i insulation displacement connector) are necessary to create an AS-i network.

The As-i fieldbus is provided with voltage by a power supply source.

The sensors and electrovalves connected to the fieldbus are controlled by the master module.
Every Master sends the information to the PLC and controls up to 62 units (C-TOP's).

The interconnection is made with a preformed cable. The preformed cable is used for transmitting information as well as a power supply of the electrovlaves and detectors. An AS-i version C-TOP must always be installed with inductive detectors and 24V DC.
The preformed cables and bus cables of the C-TOP's are connected by means of insulation displacement connectors, thus, the cables connecting every C-TOP with the control system are not necessary.

Materials and Options

Base: PPO + GF
Cover :Transparent PC
Gaskets: EPDM 

External detector (Detection of the seat lift when it cannot be detected inside the C-TOP).
Materials for work under extreme conditions (PSU cover).
Segment with 4 inputs y 4 outputs in AS-i 2.1 (31 slaves).

Document № FT.C-TOP AS-i bus.3_ES
Title C-TOP con Comunicación AS-i (bus de campo)
File type .pdf
Summary El cabezal de control C-TOP con comunicación AS-i (Actuator Sensor Interface) está diseñado o pensado para el caso de automatización de válvulas.
    Download
  • E-mail
Document № FT.C-TOP AS-i bus.3_EN
Title C-TOP with AS-i communication (fieldbus)
File type .pdf
Summary The C-TOP control unit with the AS-i (Actuator Sensor Interface) communication is designed for automation of valves.
    Download
  • E-mail
Document № FT.C-TOP AS-i bus.3_FR
Title C-TOP avec communication AS-i (bus de terrain)
File type .pdf
Summary Le boîtier de contrôle C-TOP avec communication AS-i (Vérin Senseur Interface) est conçu dans le cas d'automatisation de vannes.
    Download
  • E-mail
Document № FT.C-TOP AS-i bus.3_DE
Title C-TOP mit AS-I Kommunikation (Feldbus)
File type .pdf
Summary Das C-TOP-Steuergerät mit der AS-i (Actuator Sensor Interface) Kommunikation ist für die Automatisierung von Ventilen konzipiert
    Download
  • E-mail
Document № FT.C-TOP AS-i bus.3_IT
Title C-TOP con comunicazione AS-i (bus di campo)
File type .pdf
Summary La testata di controllo C-TOP con comunicazione AS-i (Attuatore Sensore Interfaccia) è stata progettata e pensata in caso di automazione di valvole.
    Download
  • E-mail
Document № FT.C-TOP AS-i bus.3_RU.pdf
Title C-TOP с коммуникацией AS-i (промышленная сеть)
File type .pdf
Summary Контрольное устройство C-TOP с коммуникацией AS-i предназначено для автоматизации клапанов.
    Download
  • E-mail
Document № FT.C-TOP AS-i bus.3_CN
Title C-TOP带AS-i的通信智能控制器 (现场总线)
File type .pdf
Summary C-TOP带AS-i的通信智能控制器 (传感器接口) 是专门为气动类阀门提供智能控制反 馈单元 (气动蝶阀、气动球阀、气动单座阀、防混阀等)。
    Download
  • E-mail
Document № 10.420.30.00ES_RevB
Title INSTRUCCIONES DE INSTALACIÓN, SERVICIO Y MANTENIMIENTO Cabezal de control C-TOP
File type .pdf
Summary El C-TOP es un cabezal de control neumático diseñado para asegurar un control óptimo de las válvulas de proceso de INOXPA.
    Download
  • E-mail
Document № 10.420.30.00EN_RevB
Title INSTALLATION, SERVICE AND MAINTENANCE INSTRUCTIONS C-TOP control head
File type .pdf
Summary The C-TOP is a pneumatic control head designed to assure the optimum control of INOXPA process valves.
    Download
  • E-mail
Document № 10.420.30.00FR_RevB
Title INSTRUCTIONS D'INSTALLATION, SERVICE ET ENTRETIEN Tête de commande C-TOP
File type .pdf
Summary La C-TOP est une tête de commande pneumatique conçue pour assurer un contrôle optimum des robinets de INOXPA.
    Download
  • E-mail
Document № 10.420.30.00IT_RevB
Title ISTRUZIONI DI INSTALLAZIONE, SERVIZIO E MANUTENZIONE Testata di controllo C-TOP
File type .pdf
Summary C-TOP è una testata di controllo pneumatica progettata per garantire un controllo ottimale delle valvole di processo di INOXPA.
    Download
  • E-mail

Cookies Policy

This website uses cookies. We use cookies to personalise content and ads, to provide social media features and to analyse our traffic. We also share information about your use of our site with our social media, advertising and analytics partners who may combine it with other information that you’ve provided to them or that they’ve collected from your use of their services. However, blocking some types of cookies may affect your experience on the site and the services we can offer. Cookies policy page

Allow all cookies
Allow selection
Necessary (2)
Preferences (0)
Statistics (7)
Marketing (11)
About cookies

Necessary cookies help make a website usable by enabling basic functions like page navigation and access to secure areas of the website. The website cannot function properly without these cookies.

Preference cookies enable a website to remember information that changes the way the website behaves or looks, like your preferred language or the region that you are in.

Statistic cookies help website owners to understand how visitors interact with websites by collecting and reporting information anonymously

Marketing cookies are used to track visitors across websites. The intention is to display ads that are relevant and engaging for the individual user and thereby more valuable for publishers and third party advertisers.

Name Provider Purpose Expiry Type
cc_cookie_accept www.inoxpa.com Stores the user's cookie consent state for the current domain 1 year HTTP
PHPSESSID www.inoxpa.com Preserves user session state across page requests. Session HTTP
collect Google Used to send data to Google Analytics about the visitor's device and behavior. Tracks the visitor across devices and marketing channels. Session Pixel
_ga Google Registers a unique ID that is used to generate statistical data on how the visitor uses the website. 2 years HTTP
_ga_# www.inoxpa.com Used by Google Analytics to collect data on the number of times a user has visited the website as well as dates for the first and most recent visit. 2 years HTTP
_gat_ Google Used by Google Analytics to throttle request rate 1 day HTTP
_gid Google Registers a unique ID that is used to generate statistical data on how the visitor uses the website. 1 day HTTP
fr Facebook Registers a unique ID that is used to generate statistical data on how the visitor uses the website. 3 months HTTP
_fbp Facebook Registers a unique ID that is used to generate statistical data on how the visitor uses the website. 3 months HTTP
IDE Google Used by Google DoubleClick to register and report the website user's actions after viewing or clicking one of the advertiser's ads with the purpose of measuring the efficacy of an ad and to present targeted ads to the user. 1 year HTTP
ads/ga-audiences Google Used by Google AdWords to re-engage visitors that are likely to convert to customers based on the visitor's online behaviour across websites. Session Pixel
VISITOR_INFO1_LIVE YouTube Tries to estimate the users' bandwidth on pages with integrated YouTube videos. 179 days HTTP
YSC YouTube Registers a unique ID to keep statistics of what videos from YouTube the user has seen. Session HTTP
yt-remote-cast-installed YouTube Stores the user's video player preferences using embedded YouTube video. Session HTML
yt-remote-connected-devices YouTube Stores the user's video player preferences using embedded YouTube video. Persistent HTML
yt-remote-device-id YouTube Stores the user's video player preferences using embedded YouTube video. Persistent HTML
yt-remote-fast-check-period YouTube Stores the user's video player preferences using embedded YouTube video. Session HTML
yt-remote-session-app YouTube Stores the user's video player preferences using embedded YouTube video. Session HTML
yt-remote-session-app YouTube Stores the user's video player preferences using embedded YouTube video. Session HTML
yt-remote-session-name YouTube Stores the user's video player preferences using embedded YouTube video. Session HTML
Cookies are small text files that can be used by websites to make a user's experience more efficient. The law states that we can store cookies on your device if they are strictly necessary for the operation of this site. For all other types of cookies we need your permission. This site uses different types of cookies. Some cookies are placed by third party services that appear on our pages. You can at any time change or withdraw your consent from the Cookie Declaration on our website. Learn more about who we are, how you can contact us and how we process personal data in our Privacy Policy. Please state your consent ID and date when you contact us regarding your consent.