The C-TOP control unit with the AS-i (Actuator Sensor Interface) communication is designed for automation of valves. This option is available for the valves supplied with C-TOP units (ball valve, butterfly valve, seat valves).
The C-TOP control unit with the AS-i (Actuator Sensor Interface) communication is designed for automation of valves. This option is available for the valves supplied with C-TOP units (ball valve, butterfly valve, seat valves).
The AS-i is a fieldbus system that allows to connect a network of actuators and sensors (detectors) to a control device of a higher level (Master).
Power supply, one or several master modules, bus cable (preformed cable) and the C-TOP prepared for AS-i connection (special internal card, connection cable, AS-i insulation displacement connector) are necessary to create an AS-i network.
The As-i fieldbus is provided with voltage by a power supply source.
The sensors and electrovalves connected to the fieldbus are controlled by the master module.
Every Master sends the information to the PLC and controls up to 62 units (C-TOP's).
The interconnection is made with a preformed cable. The preformed cable is used for transmitting information as well as a power supply of the electrovlaves and detectors. An AS-i version C-TOP must always be installed with inductive detectors and 24V DC.
The preformed cables and bus cables of the C-TOP's are connected by means of insulation displacement connectors, thus, the cables connecting every C-TOP with the control system are not necessary.
AS-i bus offers an easy, fast and economic interconnection of sensors and electrovalves (actuators). It facilitates the assembly and the start-up of the plant as the cabling is considerably reduced. It also reduces the start-up time as well as it helps to avoid possible installation errors.
The C-TOP units can be set up according to the customer’s requirements.
Configuration of solenoid valves
. Single-acting actuation - 1 solenoid valve
. Double-acting actuation - 2 solenoid valves
. Mixproof valve – 3 solenoid valves*
Configuration of detectors
The valve position is detected by means of inductive detectors.
. 1 position (closed or open valve) - 1 detector
. 2 positions (closed and open valve) - 2 detectors
. 3 positions (open valve, closed valve, Mixproof seat cleaning) - 3 detectors*
*Depending on the model
Base: PPO + GF
Cover :Transparent PC
Gaskets: EPDM
External detector (Detection of the seat lift when it cannot be detected inside the C-TOP).
Materials for work under extreme conditions (PSU cover).
Segment with 4 inputs y 4 outputs in AS-i 2.1 (31 slaves).
The AS-i is a fieldbus system that allows to connect a network of actuators and sensors (detectors) to a control device of a higher level (Master).
Power supply, one or several master modules, bus cable (preformed cable) and the C-TOP prepared for AS-i connection (special internal card, connection cable, AS-i insulation displacement connector) are necessary to create an AS-i network.
The As-i fieldbus is provided with voltage by a power supply source.
The sensors and electrovalves connected to the fieldbus are controlled by the master module.
Every Master sends the information to the PLC and controls up to 62 units (C-TOP's).
The interconnection is made with a preformed cable. The preformed cable is used for transmitting information as well as a power supply of the electrovlaves and detectors. An AS-i version C-TOP must always be installed with inductive detectors and 24V DC.
The preformed cables and bus cables of the C-TOP's are connected by means of insulation displacement connectors, thus, the cables connecting every C-TOP with the control system are not necessary.
Base: PPO + GF
Cover :Transparent PC
Gaskets: EPDM
External detector (Detection of the seat lift when it cannot be detected inside the C-TOP).
Materials for work under extreme conditions (PSU cover).
Segment with 4 inputs y 4 outputs in AS-i 2.1 (31 slaves).
Document № | FT.C-TOP AS-i bus.3_ES |
Title | C-TOP con Comunicación AS-i (bus de campo) |
File type | |
Summary | El cabezal de control C-TOP con comunicación AS-i (Actuator Sensor Interface) está diseñado o pensado para el caso de automatización de válvulas. |
|
Document № | FT.C-TOP AS-i bus.3_EN |
Title | C-TOP with AS-i communication (fieldbus) |
File type | |
Summary | The C-TOP control unit with the AS-i (Actuator Sensor Interface) communication is designed for automation of valves. |
|
Document № | FT.C-TOP AS-i bus.3_FR |
Title | C-TOP avec communication AS-i (bus de terrain) |
File type | |
Summary | Le boîtier de contrôle C-TOP avec communication AS-i (Vérin Senseur Interface) est conçu dans le cas d'automatisation de vannes. |
|
Document № | FT.C-TOP AS-i bus.3_DE |
Title | C-TOP mit AS-I Kommunikation (Feldbus) |
File type | |
Summary | Das C-TOP-Steuergerät mit der AS-i (Actuator Sensor Interface) Kommunikation ist für die Automatisierung von Ventilen konzipiert |
|
Document № | FT.C-TOP AS-i bus.3_IT |
Title | C-TOP con comunicazione AS-i (bus di campo) |
File type | |
Summary | La testata di controllo C-TOP con comunicazione AS-i (Attuatore Sensore Interfaccia) è stata progettata e pensata in caso di automazione di valvole. |
|
Document № | FT.C-TOP AS-i bus.3_RU.pdf |
Title | C-TOP с коммуникацией AS-i (промышленная сеть) |
File type | |
Summary | Контрольное устройство C-TOP с коммуникацией AS-i предназначено для автоматизации клапанов. |
|
Document № | FT.C-TOP AS-i bus.3_CN |
Title | C-TOP带AS-i的通信智能控制器 (现场总线) |
File type | |
Summary | C-TOP带AS-i的通信智能控制器 (传感器接口) 是专门为气动类阀门提供智能控制反 馈单元 (气动蝶阀、气动球阀、气动单座阀、防混阀等)。 |
|
Document № | 10.420.30.00ES_RevB |
Title | INSTRUCCIONES DE INSTALACIÓN, SERVICIO Y MANTENIMIENTO Cabezal de control C-TOP |
File type | |
Summary | El C-TOP es un cabezal de control neumático diseñado para asegurar un control óptimo de las válvulas de proceso de INOXPA. |
|
Document № | 10.420.30.00EN_RevB |
Title | INSTALLATION, SERVICE AND MAINTENANCE INSTRUCTIONS C-TOP control head |
File type | |
Summary | The C-TOP is a pneumatic control head designed to assure the optimum control of INOXPA process valves. |
|
Document № | 10.420.30.00FR_RevB |
Title | INSTRUCTIONS D'INSTALLATION, SERVICE ET ENTRETIEN Tête de commande C-TOP |
File type | |
Summary | La C-TOP est une tête de commande pneumatique conçue pour assurer un contrôle optimum des robinets de INOXPA. |
|
Document № | 10.420.30.00IT_RevB |
Title | ISTRUZIONI DI INSTALLAZIONE, SERVIZIO E MANUTENZIONE Testata di controllo C-TOP |
File type | |
Summary | C-TOP è una testata di controllo pneumatica progettata per garantire un controllo ottimale delle valvole di processo di INOXPA. |
|