Contact us
INNOVA J Overflow Single Seat Valve

INNOVA J Overflow Single Seat Valve

Request information

INNOVA J Overflow Single Seat Valve

The INNOVA type J valve is a pneumatic single seat valve designed for use as overflow valve in hygienic installations.
Its most important applications involve operating as a by-pass valve for positive displacement pumps or protecting equipment against excessive pressure.
Adjusting the screw on the upper part sets the spring pressure, which sets the valve’s closing pressure.
The valve opens when the set pressure is exceeded.
The valve comes with an actuator that enables liquid to flow during CIP cleaning processes.

Request information

INNOVA J Overflow Single Seat Valve

Design and features

Pressure range: from 0,5 to 6 bar.
Easy assembly/disassembly of internal parts by loosening a clamp fastener.
Open lantern allows visual inspection of shaft sealing.
360º adjustable body.

Materials

Parts in contact with the product AISI 316L (1.4404)
Other stainless steel parts AISI 304 (1.4301)
Gasket EPDM

Surface finish:
Internal Bright polish Ra ≤ 0,8 μm
External Matt

Options

Gaskets: HNBR or FPM.
Other connection types.
Opening pressure range: from 6 to 10 bar
for sizes DN 25, 40 and 50.
External position sensors.
Internal surface finish: Ra ≤ 0,5 μm.
Jacketed body.
Steam barrier.

Documents

Document № FT.INNOVA-J.1_ES
Title Válvula de Simple Asiento de Alivio INNOVA J
File type .pdf
Summary La válvula INNOVA tipo J es una válvula de simple asiento y accionamiento neumático diseñada como válvula de alivio en instalaciones higiénicas
    Download
  • E-mail
Document № FT.INNOVA-J.1_EN
Title Overflow Single Seat Valve INNOVA J
File type .pdf
Summary The INNOVA type J valve is a pneumatic single seat valve designed for use as overflow valve in hygienic installations
    Download
  • E-mail
Document № FT.INNOVA-J.1_FR
Title Vanne à Simple Siège de Surpression INNOVA J
File type .pdf
Summary La vanne INNOVA J est une vanne à simple siège à actionnement pneumatique conçue en tant que vanne à clapet pour être utilisée dans des installations hygiéniques
    Download
  • E-mail
Document № FT.INNOVA-J.1_DE
Title Überlauf-Einsitzventil INNOVA J
File type .pdf
Summary Das INNOVA-Ventil Typ J ist ein pneumatisches Einsitzventil, das als Überströmventil in hygienischen Anlagen eingesetzt wird.
    Download
  • E-mail
Document № FT.INNOVA-J.1_IT
Title Valvola di Sicurezza a Singola Sede INNOVA J
File type .pdf
Summary La valvola INNOVA tipo J è una valvola a singola sede con azionamento automatico progettata come valvola di sicurezza negli impianti igienici
    Download
  • E-mail
Document № FT.INNOVA-J.1_RU
Title Перепускной Односедельный Клапан INNOVA J
File type .pdf
Summary Клапан INNOVA типа J представляет собой односедельный клапан с пневматическим приводом, предназначенный для использования в качестве перепускного клапана в гигиенических установках
    Download
  • E-mail
Document № 10.245.30.01ES
Title INSTRUCCIONES DE INSTALACIÓN, SERVICIO Y MANTENIMIENTO VÁLVULA de ALIVIO de SIMPLE ASIENTO INNOVA J
File type .pdf
Summary La válvula INNOVA J es una válvula de simple asiento y accionamiento neumático. La presión del cierre de la válvula viene dada por la presión del muelle, que puede variarse mediante la regulación del tornillo situado en la parte superior
    Download
  • E-mail
Document № 10.245.30.01EN
Title INSTALLATION, SERVICE AND MAINTENANCE INSTRUCTIONS SINGLE SEAT RELIEF VALVE INNOVA J
File type .pdf
Summary INNOVA J (relief) valve is pneumatically actuated single-seat valve .Closing pressure of the valve is set by the spring pressure, which can be regulated by means of the screw located on the top of the valve. When the set pressure exceeds, valve opens.
    Download
  • E-mail
Document № 10.245.30.01FR
Title INSTRUCTIONS RELATIVES À L’INSTALLATION, À LA MISE EN SERVICE ET À LA MAINTENANCE VANNE À CLAPET SIMPLE SIÈGE INNOVA J
File type .pdf
Summary La vanne INNOVA J est une vanne simple siège à commande pneumatique. La pression de fermeture de la vanne est donnée par la pression du ressort qui peut être modifiée en ajustant la vis située sur la partie supérieure. Dès lors que cette pression de réglage est dépassée, la vanne s’ouvre
    Download
  • E-mail